Icon | Key | Unit | Range | Description | Default value |
---|---|---|---|---|---|
UPPER_THRESHOLD | m + datum | If an upper threshold is set, water will only flow out of the model through this inlet until the water level at the point of this inlet is equal to or less than the threshold. If the threshold is not set, the amount of water flowing out is not limited in this fashion. | None |
This attribute can be defined as values over time, using an array of values defining interpolation-time. This allows users to more dynamically define the target water level this outlet maintains.
Notes
- The INLET_Q should be 0 or negative. Otherwise, the inlet is not configured to let water flow out.
- When using a dynamic UPPER_THRESHOLD, a maximum of 10.000 values (5.000 pairs) can be defined.