Inlet upper threshold (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Overlay | {{Overlay keys|<onlyinclude> | ||
|key= | {{Overlay keys|type=row|group=Water Overlay | ||
|key=UPPER_THRESHOLD | |||
|unit={{mdatum}} | |unit={{mdatum}} | ||
|description=If an upper threshold is set, water will only flow out of the model through this [[Inlet (Water Overlay)|inlet]] until the water level at the point of this inlet is equal to or less than the threshold. If the threshold is not set, the amount of water flowing out is not limited in this fashion. | |description=If an upper threshold is set, water will only flow out of the model through this [[Inlet (Water Overlay)|inlet]] until the water level at the point of this inlet is equal to or less than the threshold. If the threshold is not set, the amount of water flowing out is not limited in this fashion. | ||
|defaultvalue=None | |defaultvalue=None | ||
|icon= | |icon=waterwizard_icon_upper_threshold.png | ||
}} | }}</onlyinclude>}} | ||
This attribute can be defined as [[time sequence (Water Overlay)|values over time]], using an array of values defining {{time sequence interpolated}}. This allows users to more dynamically define the target water level this outlet maintains. | This attribute can be defined as [[time sequence (Water Overlay)|values over time]], using an array of values defining {{time sequence interpolated}}. This allows users to more dynamically define the target water level this outlet maintains. | ||
Revision as of 12:24, 2 October 2020
Icon | Key | Unit | Range | Description | Default value |
---|---|---|---|---|---|
UPPER_THRESHOLD | m + datum | If an upper threshold is set, water will only flow out of the model through this inlet until the water level at the point of this inlet is equal to or less than the threshold. If the threshold is not set, the amount of water flowing out is not limited in this fashion. | None |
This attribute can be defined as values over time, using an array of values defining interpolation-time. This allows users to more dynamically define the target water level this outlet maintains.
Notes
- The INLET_Q should be 0 or negative. Otherwise, the inlet is not configured to let water flow out.
- When using a dynamic UPPER_THRESHOLD, a maximum of 10.000 values (5.000 pairs) can be defined.