Pump q (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(7 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Overlay attribute
{{Overlay keys|<onlyinclude>
|attribute=[[Pump_q_(Water_Overlay)|PUMP_Q]]
{{Overlay keys|type=row|group=Water Overlay
|key=PUMP_Q
|unit=m3/s
|unit=m3/s
|description=The speed at which water is pumped from the lower end-point to the higher end-point.
|description=The speed at which water is pumped from the lower end-point to the higher end-point.
|defaultvalue=n/a
|defaultvalue=n/a
|icon=[[File:waterwizard_icon_pump_q.png]]
|icon=waterwizard_icon_pump_q.png
}}</onlyinclude>}}
 
This attribute can be defined as [[time sequence (Water Overlay)|values over time]], using an array of values defining {{time sequence start}}. This allows users to more dynamically define the maximum throughput and operational direction of the pump.
 
{{article end
|notes=
* The direction the pump pumps in can be reversed by configuring a negative PUMP_Q.
* When using a dynamic PUMP_Q, a maximum of {{array max|pairs}} can be defined.
}}
}}


{{WaterOverlay object nav}}
{{WaterOverlay hydraulic structure nav}}

Latest revision as of 12:25, 2 October 2020

This attribute can be defined as values over time, using an array of values defining start-time. This allows users to more dynamically define the maximum throughput and operational direction of the pump.

Notes

  • The direction the pump pumps in can be reversed by configuring a negative PUMP_Q.
  • When using a dynamic PUMP_Q, a maximum of 10.000 values (5.000 pairs) can be defined.