Groundwater level formula (Water Overlay)

From Tygron Support wiki
Revision as of 13:00, 25 January 2024 by Frank@tygron.nl (talk | contribs)
Jump to navigation Jump to search

Groundwater level is calculated per cell.

Where:

= The height (column) of the saturated zone.
= The amount of water in the saturated zone. The height of the water column if the equivalent amount of water was placed on the surface.
= The WATER_STORAGE_PERCENTAGE of the underground terrain type, used here as a fraction.
= The groundwater level, relative to datum. Also known as the watertable.
= the datum height of the surface of cell c, set by the elevation or a Terrain elevation prequel.
= The ground bottom distance of the cell c, defined by a Bottom distance prequel or a general GROUND_BOTTOM_DISTANCE_M of the Water Overlay.