Breach flow formula (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 37: Line 37:
: [[Surface model (Water Overlay)|Surface model]]
: [[Surface model (Water Overlay)|Surface model]]


{{Template:WaterOverlay formula nav}}
{{WaterOverlay formula nav}}

Revision as of 12:05, 14 August 2020

Flow through breaches is calculated based on the weir formula, including the consideration between free flow and submerged flow situations. The weir formula is supplied with the breach width (as stand-in for the weir width), which is always calculated with the breach growth formula before calculating the weir flow.

For the entry area, the area where the water originates from, the following also applies:

Each timestep, the external water level is changed based on the amount of water flowing in or out.

t=0 we,t = we,0
otherwise we,t = we,t-1 - ( (Δw * cell) / Ae )

Where:

  • Δw = The water flow which takes place (out of the virtual external water source)
  • cell = Cell size
  • we,t = The water level of the entry area at time t.
  • we,0 = The water level of the entry area; In case of an external area: EXTERNAL_WATER_LEVEL of the breach.
  • Ae = The size of in the entry area; In case of an external area: EXTERNAL_AREA of the breach.

Notes

  • The water level we cannot become lower than the surface height se, defined by EXTERNAL_SURFACE_LEVEL in case of an external entry area. In case of an input area within the project, the surface height is determined per grid cell.