Revision as of 11:14, 4 December 2020

Underground infiltration (from the unsaturated zone to the saturated zone) is calculated per cell.

First the height of the unsaturated zone is calculated.

Hunsat = Hsurface - WLunderground

Then the ratio of water amount to unsaturated height is calculated.

S = Wunsat/Hunsat

Then calculate the distance of the unsaturated zone which can infiltrate.

Cinf = min( Hunsat , Δt * Iund )

Finally, calculate the actual amount of water infiltrating.

Δw = Cinf * S

Where:

  • Δw = The underground infiltration which takes place.
  • Δt = Computational timestep.
  • Hunsat = The height of the unsaturated zone.
  • S = Ratio of water to height in the unsaturated zone.
  • Cinf = The height in the unsaturated zone which can be subject to infiltration to the saturated zone.
  • Wunset = The amount of water in the unsaturated zone. The height of the water column if the equivalent amount of water was placed on the surface.
  • WLunderground = The groundwater level, relative to datum.
  • Hsurface = The terrain height in the cell, relative to datum.
  • Iund = The GROUND_INFILTRATION_MD of the underground terrain type.

Related

The following topics are related to this formula.

Formulas
Groundwater level formula
Surface infiltration formula
Underground seepage formula
Models
Underground model
Infiltration model
Tracer flow model