Ground bottom flow formula (Water Overlay)

From Tygron Support wiki
Revision as of 08:57, 28 August 2020 by Frank@tygron.nl (talk | contribs)
Jump to navigation Jump to search

Underground seepage (from (or to) outside the project area) is calculated per cell.

The water level change due to seepage is calculated using the following formula:

The external seepage head is variable over time by the introduction of hv,t

Finally, calculate the actual amount of water seeping into (or out of) the ground from the bottom.

Where:

  • = The water level change due to seepage, in meters.
  • = Computational timestep in seconds.
  • = Ground water head in the grid cell.
  • = additional ground water level (or head) of the external zone causing the seepage at time t, in meters
  • = constant ground water level (or head) of the external zone causing the seepage, in meters
  • = additional variation of seepage head over time
  • = resistance of the separating layer in days
  • = water storage fraction of the soil
  • = seeped in water in m

Notes

  • and can both be provided as spatially variable values.
  • can be provided as a set of values, variable over time.