Surface flow formula (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(10 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
Imbalances in water levels across the grid drive the flow of water until a state of equilibrium is reached in terms of '' | Imbalances in water levels across the grid drive the flow of water until a state of equilibrium is reached in terms of ''h'' (the height of the water column) and flux. Behavior of the flow is described by a second-order semi-discrete central-upwind scheme produced by Kurganov and Petrova (2007)<ref name="Kurganov2"/>, which is based on the 2-D Saint-Venant equations (a.k.a. shallow water equations): | ||
:<math> | :<math> | ||
Line 5: | Line 5: | ||
\frac{\partial h}{\partial t} &+ \frac{\partial (hu)}{\partial x} + \frac{\partial (hv)}{\partial y} = 0,\\[3pt] | \frac{\partial h}{\partial t} &+ \frac{\partial (hu)}{\partial x} + \frac{\partial (hv)}{\partial y} = 0,\\[3pt] | ||
\frac{\partial (hu)}{\partial t} &+ \frac{\partial}{\partial x} \left( hu^2 + \frac{1}{2} gh^2 \right) + \frac{\partial (huv)}{\partial y} = -gh \frac{\partial B}{\partial x} - ghn^2u \sqrt{u^2 + v^2} h^{-\frac{4}{3}},\\[3pt] | \frac{\partial (hu)}{\partial t} &+ \frac{\partial}{\partial x} \left( hu^2 + \frac{1}{2} gh^2 \right) + \frac{\partial (huv)}{\partial y} = -gh \frac{\partial B}{\partial x} - ghn^2u \sqrt{u^2 + v^2} h^{-\frac{4}{3}},\\[3pt] | ||
\frac{\partial (hv)}{\partial t} &+ \frac{\partial (huv)}{\partial x} + \frac{\partial}{\partial y} \left( hv^2 + \frac{1}{2} gh^2 \right) = -gh \frac{\partial B}{\partial y} - ghn^ | \frac{\partial (hv)}{\partial t} &+ \frac{\partial (huv)}{\partial x} + \frac{\partial}{\partial y} \left( hv^2 + \frac{1}{2} gh^2 \right) = -gh \frac{\partial B}{\partial y} - ghn^2v \sqrt{u^2 + v^2} h^{-\frac{4}{3}}, | ||
\end{align} | \end{align} | ||
</math> | </math> | ||
Line 25: | Line 25: | ||
|} | |} | ||
= | {{article end | ||
|seealso= | |||
* [[Surface model (Water Overlay)|Surface model]] | |||
* [[Result type (Water Overlay)|Water overlay result types]] | |||
* [[Manning_value_(Function_Value)|Manning value]] | |||
|references= | |||
<references> | <references> | ||
<ref name="Kurganov2">Kurganov A, Petrova G (2007) ∙ A Second-Order Well-Balanced Positivity Preserving Central-Upwind Scheme for the Saint-Venant System ∙ found at: http://www.math.tamu.edu/~gpetrova/KPSV.pdf (last visited 2019-04-11)</ref> | <ref name="Kurganov2">Kurganov A, Petrova G (2007) ∙ A Second-Order Well-Balanced Positivity Preserving Central-Upwind Scheme for the Saint-Venant System ∙ found at: http://www.math.tamu.edu/~gpetrova/KPSV.pdf (last visited 2019-04-11)</ref> | ||
</references> | </references> | ||
}} | |||
{{Template: | {{Template:WaterOverlay formula nav}} |
Latest revision as of 09:03, 29 January 2024
Imbalances in water levels across the grid drive the flow of water until a state of equilibrium is reached in terms of h (the height of the water column) and flux. Behavior of the flow is described by a second-order semi-discrete central-upwind scheme produced by Kurganov and Petrova (2007)[1], which is based on the 2-D Saint-Venant equations (a.k.a. shallow water equations):
where
u is the velocity in the x-direction v is the velocity in the y-direction h is the water depth B is the bottom elevation g is the acceleration due to gravity n is the Gauckler–Manning coefficient
See also
References
- ↑ Kurganov A, Petrova G (2007) ∙ A Second-Order Well-Balanced Positivity Preserving Central-Upwind Scheme for the Saint-Venant System ∙ found at: http://www.math.tamu.edu/~gpetrova/KPSV.pdf (last visited 2019-04-11)