A sewer area is part of the definition of a system of sewers in the specified area. Sewer storage is present in the hydrological model wherever the sewer area intersects with a {{inlink|Sewered constructions|sewered construction}}.
A sewer area is part of the definition of a [[sewer model (Water Overlay)|system of sewers]] in the specified area. A sewer is assumed to be present in all locations where a sewer area intersects with a [[Sewered (Water Overlay)| sewered building]].
 
In other words, a sewer is present if:
* It is covered by a [[building]] with a [[Sewered (Water Overlay)|SEWERED]] attribute > 0.
* It is covered by a sewer area with a [[Sewer storage (Water Overlay)|SEWER_STORAGE]] attribute > 0.
 
A sewer area can also pump stored sewer water to an [[External area (Water Overlay)|external area]] outside the project. However, water that has been pumped out will remain in the external area and cannot be pumped back. By default sewers do not pump water to external areas.
A sewer area can also pump stored sewer water to an [[External area (Water Overlay)|external area]] outside the project. However, water that has been pumped out will remain in the external area and cannot be pumped back. By default sewers do not pump water to external areas.


{{Overlay attribute
{{Overlay keys|suppresscategory=true|
|attribute=[[Sewer_storage_(Water_Overlay)|SEWER_STORAGE]]
{{:Sewer storage (Water Overlay)}}
|unit=m
{{:Sewer pump speed (Water Overlay)}}
|description=The maximum height the water can reach in this sewer. This value, multiplied by the surface area of the sewered constructions the sewer area intersects with, forms the total amount of water this sewer can store.
}}
|defaultvalue=n/a
 
|icon=[[File:waterwizard_icon_sewer_storage.png]]
{{article end
|attribute2=[[Sewer_pump_speed_(Water_Overlay)|SEWER_PUMP_SPEED]]
|notes=
|unit2=m3/s
* With the [[Water Overlay Wizard]], [[How to generate a sewer|sewers can be generated]] based on [[neighborhood]]s in the project.
|description2=The amount of water per second, removed from the sewer by pumping it to an external area outside the project. It cannot be pumped back once it is in the external area.
* Water pumped out of a sewer cannot be pumped back once it has left the hydrological model.
|defaultvalue2=0
|howtos=
|icon2=[[File:waterwizard_icon_sewer_pump_speed.png]]
* [[How to generate a sewer]]
|seealso=
* [[Sewer model (Water Overlay)]]
* [[Sewer overflow (Water Overlay)]]
}}
}}


Sewers do not have default storage amount, but when generating them automatically in the {{inlink|lcase=1|Configuration wizard}}, suggested values are 0,007m for older sewers and 0,04 for newer sewers.
{{WaterOverlay hydrological features nav}}
{{WaterOverlay object nav}}

Latest revision as of 14:59, 6 October 2022

A sewer area is part of the definition of a system of sewers in the specified area. A sewer is assumed to be present in all locations where a sewer area intersects with a sewered building.

In other words, a sewer is present if:

A sewer area can also pump stored sewer water to an external area outside the project. However, water that has been pumped out will remain in the external area and cannot be pumped back. By default sewers do not pump water to external areas.