Sewer pump speed (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{Overlay | {{Overlay keys|<onlyinclude> | ||
| | {{Overlay keys|type=row|group=Water Overlay | ||
|key=SEWER_PUMP_SPEED | |||
|unit=m<sup>3</sup>/s | |unit=m<sup>3</sup>/s | ||
|description=The amount of water removed from the sewer per second, by pumping it to an external area outside the project. | |description=The amount of water removed from the sewer per second, by pumping it to an external area outside the project. | ||
|defaultvalue=0 | |defaultvalue=0 | ||
|icon= | |icon=waterwizard_icon_sewer_pump_speed.png | ||
}} | }}</onlyinclude>}} | ||
This attribute can be defined as [[time sequence (Water Overlay)|values over time]], using an array of values defining {{time sequence start}}. This allows users to more dynamically define how fast water is removed from the model. | |||
{{article end | |||
|notes= | |||
* Water pumped out of a sewer cannot be pumped back once it is in the external area. | * Water pumped out of a sewer cannot be pumped back once it is in the external area. | ||
* The sewer pump speed may never be negative, as this would conceptually result in water being pumped into the sewer from outside the project area. | * The sewer pump speed may never be negative, as this would conceptually result in water being pumped into the sewer from outside the project area. | ||
* When using a dynamic SEWER_PUMP_SPEED, a maximum of {{array max|pairs}} can be defined. | |||
* [[Sewer model (Water Overlay) | |seealso= | ||
* [[Sewer model (Water Overlay)]] | |||
}} | |||
{{WaterOverlay hydrological features nav}} | {{WaterOverlay hydrological features nav}} |
Latest revision as of 11:27, 2 October 2020
Icon | Key | Unit | Range | Description | Default value |
---|---|---|---|---|---|
SEWER_PUMP_SPEED | m3/s | The amount of water removed from the sewer per second, by pumping it to an external area outside the project. | 0 |
This attribute can be defined as values over time, using an array of values defining start-time. This allows users to more dynamically define how fast water is removed from the model.
Notes
- Water pumped out of a sewer cannot be pumped back once it is in the external area.
- The sewer pump speed may never be negative, as this would conceptually result in water being pumped into the sewer from outside the project area.
- When using a dynamic SEWER_PUMP_SPEED, a maximum of 10.000 values (5.000 pairs) can be defined.