Breach measurement distance m (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
Maxim@tygron.com (talk | contribs)
No edit summary
Line 1: Line 1:
[[File:Wateroverlay_wizard_breach_measurement_distance_m.png|thumb|right|Breach measurement distance m width can be configured in ''Breach Growth'' step of a [[Flooding Overlay]] wizard.]]
[[File:Wateroverlay_wizard_breach_measurement_distance_m.png|thumb|right|Breach measurement distance m can be configured in ''Breach Growth'' step of a [[Flooding Overlay]] wizard.]]
{{Overlay attributes|<onlyinclude>
{{Overlay attributes|<onlyinclude>
{{Overlay attributes|type=row|overlay=Water  
{{Overlay attributes|type=row|overlay=Water  
Line 12: Line 12:
{{article end
{{article end
|notes=
|notes=
* This distance is only taken into account when not using a manual defined [[Breach level area (Water Overlay)|Breach level area]].
* This distance is only taken into account when not using a manually defined [[Breach level area (Water Overlay)|Breach level area]].
* In order to place the measurement the breach area must also have a [[Breach_angle_(Water_Overlay)|BREACH_ANGLE]]. Together they determine the location at which the point of measurement is placed.
* In order to place the measurement the breach area must also have a [[Breach_angle_(Water_Overlay)|BREACH_ANGLE]]. Together they determine the location at which the point of measurement is placed.
* The downstream water level of the breach is used in the [[Breach_growth_formula_(Water_Overlay)|Verheij–van der Knaap growth formula]].
* The downstream water level of the breach is used in the [[Breach_growth_formula_(Water_Overlay)|Verheij–van der Knaap growth formula]].
* Only when the area behind the breach is lower then the breach level itself the measurement point can be placed. This prevents invalid measurement points, for example when it is placed on top of a [[building]].
* Only when the area behind the breach is lower than the breach level itself the measurement point can be placed. This prevents invalid measurement points, for example when it is placed on top of a [[building]].
|seealso=
|seealso=
* [[Breach flow formula (Water Overlay)]]
* [[Breach flow formula (Water Overlay)]]

Revision as of 14:36, 2 July 2026

Breach measurement distance m can be configured in Breach Growth step of a Flooding Overlay wizard.

Notes

  • This distance is only taken into account when not using a manually defined Breach level area.
  • In order to place the measurement the breach area must also have a BREACH_ANGLE. Together they determine the location at which the point of measurement is placed.
  • The downstream water level of the breach is used in the Verheij–van der Knaap growth formula.
  • Only when the area behind the breach is lower than the breach level itself the measurement point can be placed. This prevents invalid measurement points, for example when it is placed on top of a building.

See also