Water manning (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(30 intermediate revisions by 7 users not shown)
Line 1: Line 1:
{{Overlay attribute
[[File:Manning_value.png|thumb|200px|right|The default function values for a number of buildings. The user can easily change these values.]]
|attribute=WATER_MANNING
{{Building attributes
|unit=s/(m<sup>1/3</sup>)
| <onlyinclude>
|functionvalue=Manning Value
{{Building attributes|type=row|group=Water Overlay
|description=The Gauckler–Manning coefficient of the construction.
|attribute=WATER_MANNING
|icon=[[File:waterwizard_icon_manning.png]]
|unit=s/(m<sup>1/3</sup>)
|functionvalue=Manning Value
|description=The Gauckler–Manning coefficient of the building.
|icon=waterwizard_icon_manning.png
|range=0.01 to 0.255
}} </onlyinclude>
}}
}}
====Manning value (construction)====
Constructions have an inherent "roughness", which influences how fast water can flow across the surface. This is known as the Manning coefficient or Manning value.


==Notes==
[[Building]]s have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (''n'').
* If no construction is present in any location, the {{inlink|WATER_MANNING_surface|WATER_MANNING}} value of the surface terrain present is used instead.
{{clear}}
{{article end
|notes=
* The [[Manning prequel (Water Overlay)|manning value]] can alternatively be provided as a [[prequel]].
* The default function values are derived from online accessible databases<ref name="WikiEngineer"/> and are readily adjustable by the user.
* If no Buildings are present on a [[Terrain]], the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain is used.
|seealso=
* [[Surface flow formula (Water Overlay)]]
* [[Surface model (Water Overlay)]]
*[[Terrain water manning (Water Overlay)]]
* [[Manning prequel (Water Overlay)]]
|references=
<references>
<ref name="WikiEngineer">WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients </ref>
</references>
}}


{{Template:WaterOverlay_attribute_nav}}
{{WaterOverlay hydrological building attribute nav}}

Latest revision as of 09:30, 27 February 2024

The default function values for a number of buildings. The user can easily change these values.

Buildings have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (n).

Notes

  • The manning value can alternatively be provided as a prequel.
  • The default function values are derived from online accessible databases[1] and are readily adjustable by the user.
  • If no Buildings are present on a Terrain, the WATER_MANNING value of the surface terrain is used.

See also

References

  1. WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients