Unsaturated fraction (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 10: | Line 10: | ||
|notes= | |notes= | ||
* The maximum storage capacity of underground terrains can be configured with the [[Terrain water storage percentage (Water Overlay)|Water storage percentage]] attribute. | * The maximum storage capacity of underground terrains can be configured with the [[Terrain water storage percentage (Water Overlay)|Water storage percentage]] attribute. | ||
* Note that this fraction is relative to the maximum water storage capacity of the terrain and not relative to the underground terrain volume. This amounts to the following formula: <br>Amount of water in the unsaturated zone = relative ground water depth * [[Terrain water storage percentage (Water Overlay)|WATER_STORAGE_PERCENTAGE]] * UNSATURATED_FRACTION. | * Note that this fraction is relative to the maximum water storage capacity of the terrain and not relative to the underground terrain volume. This amounts to the following formula: <br>Amount of water in the unsaturated zone = relative ground water depth * [[Terrain water storage percentage (Water Overlay)|WATER_STORAGE_PERCENTAGE]] * [[Unsaturated fraction (Water Overlay)|UNSATURATED_FRACTION]]. | ||
* For example, an underground terrain with a water storage of 25% and a ground water depth of 1 m and a configured unsaturated fraction of 0.25 will result in 0.0625 meter water in the unsaturated zone. (25% of 25% of the total volume of 1 m3) | * For example, an underground terrain with a water storage of 25% and a ground water depth of 1 m and a configured unsaturated fraction of 0.25 will result in 0.0625 meter water in the unsaturated zone. (25% of 25% of the total volume of 1 m3) | ||
|seealso= | |seealso= |
Revision as of 13:41, 10 February 2022
Icon | Attribute | Unit | Range | Description | Default value |
---|---|---|---|---|---|
UNSATURATED_FRACTION | fraction | The initial fraction of the maximum storage capacity of the unsaturated zone which is filled with water. | 0 |
Notes
- The maximum storage capacity of underground terrains can be configured with the Water storage percentage attribute.
- Note that this fraction is relative to the maximum water storage capacity of the terrain and not relative to the underground terrain volume. This amounts to the following formula:
Amount of water in the unsaturated zone = relative ground water depth * WATER_STORAGE_PERCENTAGE * UNSATURATED_FRACTION. - For example, an underground terrain with a water storage of 25% and a ground water depth of 1 m and a configured unsaturated fraction of 0.25 will result in 0.0625 meter water in the unsaturated zone. (25% of 25% of the total volume of 1 m3)