Ground max storage result type (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(11 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{| class="wikitable"
{{result types|<onlyinclude>
! Image
{{result types|type=row|overlay=Water
! Result type
|name=GROUND_MAX_STORAGE
! Unit
|icon=overlay_icon_water_ground_max_storage.png
! Display mode
|unit=m (mm)&sup1;
! Description
|mode=[[Result type (Water Overlay)#Maximum_resulttype|Maximum]]
|-
|description=The highest (effective) amount of water in both the unsaturated and saturated zone during the simulation.  
|[[File:overlay_icon_water_ground_max_storage.png|25px|center]]
}}</onlyinclude>}}
|GROUND_MAX_STORAGE
 
|m (mm)&sup1;
{{Grid Overlay unit display information}}
|[[Result_type_(Water_Overlay)#Maximum_resulttype|Maximum]]
{{article end
|The (effective) amount of water in the underground unsaturated zone.
|notes=
|}
* This result type requires the [[Ground water (Water Overlay)|Ground water mode]] to be set to INFILTRATION_ONLY, or to COMPLETE.
{{Unit disclaimer (Water Overlay)}}
* The displayed result is the height of the water column below the surface. It is the sum of the amount water in the saturated zone and the unsaturated zone, where the amount is represented as the water column. This value can be used to validate water balances and comparisons with values such as water on surface, rain, bottom boundary flow and evaporation.
{{Template:WaterOverlay_result_nav}}
* In the ground, water in the unsaturated zone is assumed to be equally spread across the entire height of the unsaturated zone.
{{Water Module buttons}}
* To obtain the amount of water in the saturated zone, the Water datum height is converted using the surface datum height, the bottom distance and the water storage percentage.
|seealso=
* [[Ground model (Water Overlay)]]
* [[Ground infiltration formula (Water Overlay)]]
* [[Ground evaporation formula (Water Overlay)]]
* [[Surface infiltration formula (Water Overlay)]]
}}
{{WaterOverlay result nav}}

Latest revision as of 11:36, 26 April 2024

¹ the units between () are as displayed in the 3D client. If exported to GeoTiff the SI-convention is used: meters (m) and seconds (s).

Notes

  • This result type requires the Ground water mode to be set to INFILTRATION_ONLY, or to COMPLETE.
  • The displayed result is the height of the water column below the surface. It is the sum of the amount water in the saturated zone and the unsaturated zone, where the amount is represented as the water column. This value can be used to validate water balances and comparisons with values such as water on surface, rain, bottom boundary flow and evaporation.
  • In the ground, water in the unsaturated zone is assumed to be equally spread across the entire height of the unsaturated zone.
  • To obtain the amount of water in the saturated zone, the Water datum height is converted using the surface datum height, the bottom distance and the water storage percentage.

See also