Attribute Unit Description
EVAPORATION_M end-time, m An array of values, each pair indicating until what time that period of evaporation will last and what amount evaporates in that period.


Notes

File:Evaporation total.png
Image of the evaporation model in the Water Module
  • A maximum of 10.000 values (5.000 pairs) can be defined.
  • Internally each period with amount values are converted to an evaporation rate per second at a particular time in the simulation.
  • The default value is set to 0.125 mm in 2 hours (0.000125 m in 7200 seconds), which corresponds to 1.5 mm per day. This value is derived from

See also