Notes

  • The values in this prequel grid are clamped between 0 and 1. No data values are not allowed, but negative values are interpreted as zero saturation.
  • Note that this fraction is relative to the maximum water storage capacity of the terrain and not relative to the underground terrain volume. This amounts to the following formula:
    Amount of water in the unsaturated zone = relative ground water depth * WATER_STORAGE_PERCENTAGE * UNSATURATED_FRACTION.
  • For example, an underground terrain with a water storage of 25% and a ground water depth of 1 m and a configured unsaturated fraction of 0.25 will result in 0.0625 meter water in the unsaturated zone. (25% of 25% of the total volume of 1 m3)