The sequence for the four values should be defined in order of largest to smallest depth values and are interpreted as a 0-1-1-0 transpiration factor trapezium. | The sequence for the four values should be defined in order of largest to smallest depth values and are interpreted as a 0-1-1-0 transpiration factor trapezium. | ||
[[File:Feddes_trapezium. | [[File:Feddes_trapezium.jpg]] | ||
[[File:YoutubeLogo1.jpg|thumb|left|link=https://www.youtube.com/watch?v=QTHLYorMkk4&t=1032s|Evaporation in the {{software}} (Dutch only)]]{{clear}} | [[File:YoutubeLogo1.jpg|thumb|left|link=https://www.youtube.com/watch?v=QTHLYorMkk4&t=1032s|Evaporation in the {{software}} (Dutch only)]]{{clear}} |
Revision as of 10:08, 12 February 2021
Template:Construction attributes
Constructions with a root depth are known as crops and foliage.
Constructions representing crops and foliage can draw water from the underground, allowing it to evaporate. This behaves in the same way as terrain which is configured as plants.
Feddes Trapezium
Plants can experience oxygen stress when the groundwater level is too high. The plant roots become saturated so that the plant can no longer transpire.
To simulate the oxygen stress, the ROOT_DEPTH_M can also be configured with four values instead of one, which will be interpreted using Feddes transpiration model.
In the model, when the groundwater level rises, the transpiration increases. However, at a certain point, the groundwater is too high and the transpiration decreases. Water on the surface can then still evaporate, but the plant cannot transpire anymore.
The sequence for the four values should be defined in order of largest to smallest depth values and are interpreted as a 0-1-1-0 transpiration factor trapezium.
Notes
- For crops and foliage to evaporate water, both the ROOT_DEPTH_M and the WATER_EVAPORATION_FACTOR must be appropriately configured.
- When a construction is present in any given location, the values for evaporation in the underground will overrule any values set by terrain in the same location. To model underground evaporation without a construction, set the attributes of the construction on the applicable terrain type instead.
- When a construction has a ROOT_DEPTH_M of 0, the amount of evaporation which takes place in that location is 0.
How-to's
See also
Template:WaterOverlay hydrological construction attribute nav