Surface infiltration formula (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
mNo edit summary
Line 34: Line 34:


{{Template:WaterOverlay_nav}}
{{Template:WaterOverlay_nav}}
{{Water Module buttons}}

Revision as of 16:37, 15 October 2019

Surface infiltration is calculated per cell.

First, the infiltration capacities are calculated:

Cwater = Wsurface
Ctop = max( Icon, Isurf )
Isurf = 0 if a construction is present
Icon = 0 if no construction is present

Then the actual infiltration:

Δw = min( Cwater , Δt * Ctop)

Where:

  • Δw = The surface infiltration which takes place.
  • Δt = Computational timestep.
  • Cwater = The amount of infiltration that can take place based on the amount of water on the surface.
  • Ctop = The amount of infiltration that can take place based on the infiltration values present.
  • Wsurface = The amount of water (the water column) on the surface.
  • Icon = The GROUND_INFILTRATION_MD of a construction on a specific cell (if present).
  • Isurf = The GROUND_INFILTRATION_MD of the surface terrain type. This value should be interpreted as the vertical conductivity (Kv) of the sub-soil.

Related

The following topics are related to this formula.

Formulas
Surface water level formula
Groundwater level formula
Underground infiltration formula
Models
Surface model
Underground model
Infiltration model
Substance flow model

Template:WaterOverlay nav