Line 17: Line 17:
* <math>C_{top}</math> = The amount of infiltration that can take place based on the infiltration values present.
* <math>C_{top}</math> = The amount of infiltration that can take place based on the infiltration values present.


* W<sub>surface</sub> = The amount of water (the water column) on the surface.
* <math>W_{surface}</math> = The amount of water (the water column) on the surface.
* I<sub>con</sub> = The [[Terrain ground infiltration md (Water Overlay)|GROUND_INFILTRATION_MD]] of a construction on a specific cell (if present).
* <math>I_{con}</math> = The [[Terrain ground infiltration md (Water Overlay)|GROUND_INFILTRATION_MD]] of a construction on a specific cell (if present).
* I<sub>surf</sub> = The [[Terrain ground infiltration md (Water Overlay)|GROUND_INFILTRATION_MD]] of the surface terrain type. This value should be interpreted as the vertical conductivity (Kv) of the sub-soil.
* <math>I_{surf}</math> = The [[Terrain ground infiltration md (Water Overlay)|GROUND_INFILTRATION_MD]] of the surface terrain type. This value should be interpreted as the vertical conductivity (Kv) of the sub-soil.


==Related==
==Related==

Revision as of 07:44, 17 October 2019

Surface infiltration is calculated per cell.

First, the infiltration capacities are calculated:

Cwater = Wsurface
Ctop = max( Icon, Isurf )
Isurf = 0 if a construction is present
Icon = 0 if no construction is present

Then the actual infiltration:

Δw = min( Cwater , Δt * Ctop)

Where:

  • = The surface infiltration which takes place.
  • = Computational timestep.
  • = The amount of infiltration that can take place based on the amount of water on the surface.
  • = The amount of infiltration that can take place based on the infiltration values present.
  • = The amount of water (the water column) on the surface.
  • = The GROUND_INFILTRATION_MD of a construction on a specific cell (if present).
  • = The GROUND_INFILTRATION_MD of the surface terrain type. This value should be interpreted as the vertical conductivity (Kv) of the sub-soil.