Prequel overlays can be linked to the [[Water Overlay]] to initiate particular parts of the model with more accuracy and detail. They can even be used to link result types of one Water Overlay as prequel input to another. | Prequel overlays can be linked to the [[Water Overlay]] to initiate particular parts of the model with more accuracy and detail. They can even be used to link result types of one Water Overlay as prequel input to another. | ||
{ | {{Overlay prequels|suppresscategory=true|allowselflinks=true| | ||
| | {{:Terrain elevation prequel (Water Overlay)}} | ||
{{:Surface level prequel (Water Overlay)}} | |||
{{:Groundwater depth prequel (Water Overlay)}} | |||
{{:Groundwater datum prequel (Water Overlay)}} | |||
{{:Unsaturated fraction prequel (Water Overlay)}} | |||
{{:Seepage c prequel (Water Overlay)}} | |||
{{:Seepage p prequel (Water Overlay)}} | |||
{{:Manning prequel (Water Overlay)}} | |||
}} | |||
{{WaterOverlay simulation data nav}} | {{WaterOverlay simulation data nav}} | ||
[[Category:Water Module]] | [[Category:Water Module]] |
Revision as of 08:00, 11 February 2022
Prequel overlays can be linked to the Water Overlay to initiate particular parts of the model with more accuracy and detail. They can even be used to link result types of one Water Overlay as prequel input to another.
Seepage c prequel (Water Overlay) Seepage p prequel (Water Overlay)
Name | Prequel | Underlying data | Unit | Range | No data | Description |
---|---|---|---|---|---|---|
Terrain elevation | TERRAIN_ELEVATION | Water Prequel | m datum | -10000 to 10000 | Clamped to range | Used for initializing the terrain elevation on this datum. |
Surface level | SURFACE_LEVEL | Water Prequel | m | -10000 to 10000 | Clamped to range | Used for initializing the surface water level on this datum, both in waterways and on land. |
Groundwater depth | GROUND_WATER_DEPTH | Water Prequel | m | 0 10000 | Clamped to range | Used for initializing the ground water level to these depths. |
Groundwater datum | GROUND_WATER_DATUM | Water Prequel | m datum | -10000 10000 | Clamped to range | Used for initializing the ground water level on this datum. |
Unsaturated fraction | UNSATURATED_FRACTION | Water Prequel | 0 to 1 | Clamped to range | Used for initializing the saturation of the unsaturated zone in the underground. | |
Manning | MANNING | Water Prequel | 0.01 to 0.255 | Clamped to range | Used for overriding the surface terrain's manning value. |