How to configure constant bottom boundary flow (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(10 intermediate revisions by the same user not shown)
Line 1: Line 1:
When working with the [[Underground model (Water Overlay)|full groundwater model]] of the [[Water Overlay]], underground seepage may present a significant factor in the underground water balance. For these situations, underground seepage can be configured.
When working with the [[Ground model (Water Overlay)|full groundwater model]] of the [[Water Overlay]], ground bottom flow from deeper ground layers through the bottom boundary may present a significant factor in the ground water balance. For these situations, various ground bottom flow parameters can be configured.


For seepage to be functional, the [[Bottom pressure prequel (Water Overlay)|Bottom pressure prequel]] and [[Bottom resistance prequel (Water Overlay)|Bottom resistance prequel]] are required and must be prepared beforehand.
For ground bottom flow to be functional, the [[Bottom pressure prequel (Water Overlay)|Bottom pressure prequel]] and [[Bottom resistance prequel (Water Overlay)|Bottom resistance prequel]] are required and must be prepared beforehand.


{{editor location|Overlay wizard|Water Overlay|Seepage}}
{{editor location|Overlay wizard|Water Overlay|Bottom boundary}}


{{howto|title=configure constant seepage
{{howto|title=configure constant bottom boundary flow
| Open the [[Water Overlay Wizard]], and proceed to the seepage step.
| Open the [[Water Overlay Wizard]], and proceed to the ''bottom boundary'' step.
| Opt to select seepage Grid Overlays and define the seepage factor.
| Opt to select Bottom Grid Overlays
| For the pressure Grid, import your [[Bottom pressure prequel (Water Overlay)|GeoTIFF Overlay with seepage pressure values]].
| Optionally define a [[Ground bottom pressure m (Water Overlay)|Global Pressure]].
| Ensure the uploaded GeoTiff Overlay is selected in the dropdown.
| For the Head Pressure Grid, import your [[Bottom pressure prequel (Water Overlay)|GeoTIFF Overlay with head pressure values]].
| For the resistance Grid, import your [[Bottom resistance prequel (Water Overlay)|GeoTIFF Overlay with seepage resistance values]].
| Ensure the uploaded [[GeoTIFF Overlay]] is selected in the dropdown.
| Ensure the uploaded GeoTIFF Overlay is selected in the dropdown.
| For the resistance Grid, import your [[Bottom resistance prequel (Water Overlay)|GeoTIFF Overlay with resistance values]].
| Ensure the uploaded [[GeoTIFF Overlay]] is selected in the dropdown.
| Close the configuration wizard, and [[recalculate|recalculate the Overlay]].
| Close the configuration wizard, and [[recalculate|recalculate the Overlay]].
}}
}}


{{article end
{{article end
|howtos=
* [[How to configure bottom boundary flow to vary over time (Water Overlay)]]
|seealso=
|seealso=
* [[How to configure seepage to vary over time (Water Overlay)]]
* [[Bottom resistance prequel (Water Overlay)]]
* [[Bottom resistance prequel (Water Overlay)]]
* [[Bottom pressure prequel (Water Overlay)]]
* [[Bottom pressure prequel (Water Overlay)]]
}}
}}
[[Category:Water]]

Latest revision as of 11:42, 26 April 2024

When working with the full groundwater model of the Water Overlay, ground bottom flow from deeper ground layers through the bottom boundary may present a significant factor in the ground water balance. For these situations, various ground bottom flow parameters can be configured.

For ground bottom flow to be functional, the Bottom pressure prequel and Bottom resistance prequel are required and must be prepared beforehand.

Editor → Current Situation (Ribbon tab) → Overlays (Ribbon bar) → Water Overlay (Left panel) → Configuration Wizard (Right panel) → Bottom boundary
How to configure constant bottom boundary flow:
  1. Open the Water Overlay Wizard, and proceed to the bottom boundary step.
  2. Opt to select Bottom Grid Overlays
  3. Optionally define a Global Pressure.
  4. For the Head Pressure Grid, import your GeoTIFF Overlay with head pressure values.
  5. Ensure the uploaded GeoTIFF Overlay is selected in the dropdown.
  6. For the resistance Grid, import your GeoTIFF Overlay with resistance values.
  7. Ensure the uploaded GeoTIFF Overlay is selected in the dropdown.
  8. Close the configuration wizard, and recalculate the Overlay.