Surface infiltration formula (Water Overlay)

From Tygron Support wiki
Revision as of 07:49, 17 October 2019 by Frank@tygron.nl (talk | contribs)
Jump to navigation Jump to search

Surface infiltration is calculated per cell.

First, the infiltration capacities are calculated:

Cwater = Wsurface
Ctop = max( Icon, Isurf )
Isurf = 0 if a construction is present
Icon = 0 if no construction is present

Then the actual infiltration: Failed to parse (unknown function "\math"): {\displaystyle \Delta w = min( C_{water} , \Delta t \cdot C_{top})<\math> Where: * <math>\Delta w} = The surface infiltration which takes place.

  • Δt = Computational timestep.
  • Cwater = The amount of infiltration that can take place based on the amount of water on the surface.
  • Ctop = The amount of infiltration that can take place based on the infiltration values present.
  • Wsurface = The amount of water (the water column) on the surface.
  • Icon = The GROUND_INFILTRATION_MD of a construction on a specific cell (if present).
  • Isurf = The GROUND_INFILTRATION_MD of the surface terrain type. This value should be interpreted as the vertical conductivity (Kv) of the sub-soil.

The following topics are related to this formula.

Formulas
Surface water level formula
Groundwater level formula
Underground infiltration formula
Models
Surface model
Underground model
Infiltration model
Substance flow model

Template:WaterOverlay nav