How to configure a dynamic infiltration factor for a Water Overlay: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
{{Editor location|overlay wizard|The Groundwater Overlay}} | {{Editor location|overlay wizard|The Groundwater Overlay}} | ||
{{Editor steps|title=set a dynamic | {{Editor steps|title=set configure a dynamic infiltration factor for a Water Overlay | ||
|Prepare a [[CSV]] file with the desired timing data for the [[Infiltration factor s (Water Overlay)|infiltration factor s]]. | |Prepare a [[CSV]] file with the desired timing data for the [[Infiltration factor s (Water Overlay)|infiltration factor s]]. | ||
|Open the [[Water Overlay Wizard|configuration wizard]] of the [[Groundwater Overlay]] and continue to the step concerning infiltration. | |Open the [[Water Overlay Wizard|configuration wizard]] of the [[Groundwater Overlay]] and continue to the step concerning infiltration. |
Revision as of 11:19, 3 February 2023
By default, the amount of water that can infiltrate into the unsaturated zone is linear. This page describes how to configure a changing infiltration over time by configuring the infiltration factor s attribute of a Water Overlay.
Editor → Current Situation (Ribbon tab) → Overlays (Ribbon bar) → The Groundwater Overlay (Left panel) → Configuration Wizard (Right panel)
How to set configure a dynamic infiltration factor for a Water Overlay:
- Prepare a CSV file with the desired timing data for the infiltration factor s.
- Open the configuration wizard of the Groundwater Overlay and continue to the step concerning infiltration.
- Set the infiltration factor s' mode to dynamic, and select 'Select'. This will open the CSV importing tool.
- Select 'Import new CSV'
- In the lower right of the panel, adjust the import parameters of the csv you are about to select first. This is required to interpret the file correctly.
- Select the CSV file with the desired timing data.
- The imported values now appear in the CSV importing tool. Optionally change the used time metric and verify that the data is interpreted correctly.
- The CSV importing tool can now be closed.
- Continue with the configuration wizard of the Flooding Overlay.
Notes
A dynamic infiltration factor can also be provided without a CSV. Therefore you can fill in the time and height values in the INFILTRATION_FACTOR_S attribute of the Water Overlay. Note that the time values should be in seconds if you provide an array of values this way.