In order to validate the [[Water module|water module]] implementation in the {{software}}, several shallow water related benchmarks have been performed. Internally, for the {{software}}'s build process, these [[wikipedia:Benchmark_(computing)|benchmarks]] have been mostly automated to test each implementation change made to the server and the water module in terms of code, data and hardware.
{{Water Module buttons}}
 
In order to validate the implementation of the [[Water Module|water module]] in the {{software}}, several shallow water related benchmarks have been performed. The following performed benchmarks can be reviewed:
 
'''Rainfall Benchmarks'''
* [[Stowa_2017_benchmark_(Water_Module)|STOWA-2017 benchmark (Rain water flow, hydraulic structures)]]
 
'''Flooding Benchmarks'''
* [[UK_Benchmark_1_(Water_Module)|UK Benchmark Case 1 (Sloping topography)]]
* [[UK_Benchmark_2_(Water_Module)|UK Benchmark Case 2 (Filling of floodplain)]]
* [[UK_Benchmark_3_(Water_Module)|UK Benchmark Case 3 (Momentum conservation)]]
* [[UK_Benchmark_4_(Water_Module)|UK Benchmark Case 4 (Speed of flood propagation)]]
* [[UK_Benchmark_5_(Water_Module)|UK Benchmark Case 5 (Valley flooding)]]
* [[UK_Benchmark_6_(Water_Module)|UK Benchmark Case 6 (Dambreak)]]
 
'''Groundwater Benchmarks'''
* [[Waterway level change benchmark (Water Module)|Sudden waterway level change benchmark. (Dutch Classic)]]
* [[Freatic groundwater levels benchmark (Water Module)|Freatic groundwater levels benchmark]]
* [[Bottom flow_pankow_benchmark_(Water_Module)|Pankow's bottom flow equation benchmark]]
* [[Radial_well_aquifer_benchmark_(Water_Module)|Radial well with aquifer benchmark]]
* [[Radial_well_freatic_benchmark_(Water_Module)|Radial well with freatic benchmark]]
 
'''Perform your own Benchmarks'''
* Some of the Benchmarks mentioned above are available in your own domain. Please contact {{email|support}} for more information.
* Confirm your own basic water calculations by composing a test bed in the {{software}} using the [[Testbed tutorial]].
* Check out some basic set-ups for testing using the [[Testbed water module|Water Module Testbed]] which is available in your own domain and can be found in the main menu under Edit projects.
 
Tygron has automated most of these [[wikipedia:Benchmark_(computing)|benchmarks]] for its {{software}}'s build process. This way, each implementation change made to the server and the Water Module is tested in terms of code, data and hardware.
 
'''Additional test cases'''
* [[Weir height test case (Water Module)|Weir flow test case]]
 
[[Category:Benchmarks]]

Latest revision as of 14:53, 5 March 2024


In order to validate the implementation of the water module in the Tygron Platform, several shallow water related benchmarks have been performed. The following performed benchmarks can be reviewed:

Rainfall Benchmarks

Flooding Benchmarks

Groundwater Benchmarks

Perform your own Benchmarks

  • Some of the Benchmarks mentioned above are available in your own domain. Please contact for more information.
  • Confirm your own basic water calculations by composing a test bed in the Tygron Platform using the Testbed tutorial.
  • Check out some basic set-ups for testing using the Water Module Testbed which is available in your own domain and can be found in the main menu under Edit projects.

Tygron has automated most of these benchmarks for its Tygron Platform's build process. This way, each implementation change made to the server and the Water Module is tested in terms of code, data and hardware.

Additional test cases