This benchmark performs UK EA benchmark Test 6 – Dambreak using the Water Module of the Tygron Platform.

his dambreak test case (see Appendix A.6) originates from the IMPACT project (Soares-Frazão and Zech 2002). Physical measurements were provided by the Civil Engineering Laboratory of the Université Catholique de Louvain (UCL).

Characteristics:

  • Dimensions: 20X the values below
  • Roughness: uniform manning = 0,05 m/s1/3
  • Initial conditions: 8m in reservoir, 0.4m in floodplain
  • Modelgrid resolution: 2m

Results

Measured water levels and velocities were provided by UCL for six points (G1 to G6, except for velocities at G6). The results for each point are shown below.

Velocity profiles