Revision as of 13:55, 4 April 2019
The flow created by a pump is calculated based on the lowest end point of the pump.
- Δw = min( WHlower , Δt * PS )
Where:
- Δw = The amount water water pumped from the lower to the higher endpoint.
- Δt = Computational timestep.
- WHlower = The height of the water column at the lower end of the pump, relative to the terrain.
- PS = The PUMP_Q of the pump.