Water Connection Generator: Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
Line 13: Line 13:
=== Maximum height difference ===
=== Maximum height difference ===
The height differences on the surface along the line of the water connection. This parameter can be used to detect dikes and prevent water connections under them. Additionally, this same parameter can be used to prevent connections being created for water ways that have water levels that are too far apart.
The height differences on the surface along the line of the water connection. This parameter can be used to detect dikes and prevent water connections under them. Additionally, this same parameter can be used to prevent connections being created for water ways that have water levels that are too far apart.
[[File:water_connection_max_height.jpg|400px|thumb|Two waterways with a levee in between. A stricter max height difference can prevent the creation of an unrealistic water connection.]]
[[File:water_connection_max_height.jpg|400px|thumb|left|Two waterways with a levee in between. A stricter max height difference can prevent the creation of an unrealistic water connection.]]
[[File:water_connection_height_difference.jpeg|400px|thumb|Two waterways, of which one is situated 5 meters lower than the other.]]
[[File:water_connection_height_difference.jpeg|400px|thumb|left|Two waterways, of which one is situated 5 meters lower than the other.]]


=== Width ===  
=== Width ===  

Revision as of 16:24, 5 June 2020

The Water Connection Generator enables users to generate underground buildings such as culverts using a set of parameters. This generator is useful in situations where a project misses a large number of these constructions. Generated constructions can be easily removed as well, to retry with different parameters. The parameters are explained below under Advanced Options.

WaterConnectionGenerator.png

Advanced Options

Mininimum and maximum length

Both the minimum and maximum length can be provided to limit the amount of created water constructions. The length is measured as the closest points between two water bodies.

Large road threshold

A road is considered large (and therefor impassable) when the road's size is larger than the threshold. This parameter can be used to prevent water connections crossing large roads. The large road threshold is provided as a surface size in m2.

Large road straight

Large road straight (m).

Maximum height difference

The height differences on the surface along the line of the water connection. This parameter can be used to detect dikes and prevent water connections under them. Additionally, this same parameter can be used to prevent connections being created for water ways that have water levels that are too far apart.

Two waterways with a levee in between. A stricter max height difference can prevent the creation of an unrealistic water connection.
Two waterways, of which one is situated 5 meters lower than the other.

Width

The construction will have its width set to this value when placed. The width is provided in meters.

Ignore upstream

A water connection is only created when its endpoints differ in height less than this configured value. This parameter can be used to prevent connections being created for water ways that have water levels that are too far apart. [[File:water_connection_height_difference|400px|thumb|Two waterways, of which one is situated 5 meters lower than the other. The ignore upstream parameter of

Include water bodies

When selected, both waterways and water bodies are taken into account as water terrains. When not selected, only waterways are taken into account.

Optional actions

  • The Reset to defaults action reverts the values of the advanced options back to the default settings.
  • The Remove generated action removes all generated constructions of the indicated function.