UK Benchmark 6 (Water Module): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
Line 5: Line 5:
====description====
====description====
Engine version: 2019.0.0 DEV 66.0
Engine version: 2019.0.0 DEV 66.0
Executed: 2018-07-10
Date executed: 2018-07-10


Characteristics:
Characteristics:
Line 33: Line 33:


===Benchmark 3===
===Benchmark 3===
====description====
Engine version: 2019.0.0 DEV 68.0
Date executed: 2018-07-11
Characteristics:
Test for conservation of momentum over a small obstruction. By inertia (flow changing over time) some water flows over the obstruction.
* Dimensies: zie Figuur below
* Roughness: uniform manning = 0,01 m/s1/3
* Initial condition: 0m water depth
* Resolution: 5m grid
* Boundary condition: Q(t), see figure below
[[File:Inundation benchmark 05.PNG]]
====results====
Results every 2 seconds in the middle of every despression are requested and shown below
[[File:Inundation benchmark 06.PNG]]

Revision as of 08:27, 3 August 2018

UK Benchmarks

Benchmark 2

description

Engine version: 2019.0.0 DEV 66.0 Date executed: 2018-07-10

Characteristics: A test for the evaluation of an inundation pattern and depth at low momentum over a complex topography:

  • Dimensions: 2000m X 200m
  • Roughness: uniform manning = 0,03 m/s1/3
  • Initial conditions: empty grid
  • Resolution: 20m grid
  • Boundary condition: Q(t) in North-East side of the model domain

note: the benchmark was executed on a 10m, instead of 20m

File:Inundation benchmark 01.PNG

results

Water levels every 300 secs on the centre of every depression are requested together with a map of the waterdepts at the end of simulation.

The waterdepth at the end of simulation is shown below

File:Inundation benchmark 02.PNG

And graphs of water levels at the centre of every depression:

File:Inundation benchmark 03.PNG

File:Inundation benchmark 04.PNG

Benchmark 3

description

Engine version: 2019.0.0 DEV 68.0 Date executed: 2018-07-11

Characteristics: Test for conservation of momentum over a small obstruction. By inertia (flow changing over time) some water flows over the obstruction.

  • Dimensies: zie Figuur below
  • Roughness: uniform manning = 0,01 m/s1/3
  • Initial condition: 0m water depth
  • Resolution: 5m grid
  • Boundary condition: Q(t), see figure below

File:Inundation benchmark 05.PNG

results

Results every 2 seconds in the middle of every despression are requested and shown below


File:Inundation benchmark 06.PNG