Line 6: Line 6:
|unit=m3/s
|unit=m3/s
|description=The speed at which water is pumped from the lower end-point to the higher end-point.
|description=The speed at which water is pumped from the lower end-point to the higher end-point.
|defaultvalue=0
|defaultvalue=n/a
|icon=[[File:waterwizard_icon_pump_q.png]]
|icon=[[File:waterwizard_icon_pump_q.png]]
|attribute2=[[Lower_threshold_pump_(Water_Overlay)|LOWER_THRESHOLD]]
|attribute2=[[Lower_threshold_(Water_Overlay)|LOWER_THRESHOLD]]
|unit2=m
|unit2=m
|description2=The threshold of the lower entry of the Pump. Water flows from the lower entry to the higher entry until the water level at the lower entry has reached the threshold. If not selected, the Lower Threshold will be ignored as a mechanic.
|description2=The threshold of the lower entry of the Pump. Water flows from the lower entry to the higher entry until the water level at the lower entry has reached the threshold. If not selected, the Lower Threshold will be ignored as a mechanic.
|defaultvalue2={{novalue}}
|defaultvalue2={{novalue}}
|icon2=[[File:waterwizard_icon_lower_threshold.png]]
|icon2=[[File:waterwizard_icon_lower_threshold.png]]
|attribute3=[[Upper_threshold_pump_(Water_Overlay)|UPPER_THRESHOLD]]
|attribute3=[[Upper_threshold_(Water_Overlay)|UPPER_THRESHOLD]]
|unit3=m
|unit3=m
|description3=he threshold of the higher entry of the Pump. Water flows from the lower entry to the higher entry until the water level at the higher entry has reached the threshold. If not selected, the Upper Threshold will be ignored as a mechanic.
|description3=he threshold of the higher entry of the Pump. Water flows from the lower entry to the higher entry until the water level at the higher entry has reached the threshold. If not selected, the Upper Threshold will be ignored as a mechanic.
Line 21: Line 21:
|unit4=m3/s
|unit4=m3/s
|description4=The maximum possible m3 water that can flow through this Pump.
|description4=The maximum possible m3 water that can flow through this Pump.
|defaultvalue4=0
|defaultvalue4=n/a
|icon4=[[File:waterwizard_icon_inlet_capacity.png]]
|icon4=[[File:waterwizard_icon_inlet_capacity.png]]
}}
}}
Line 28: Line 28:


==See also==
==See also==
* [[Pump_formula_(Water Overlay)|Pump Formula]]
* [[Pump Formula (Water Overlay)|Pump Formula]]
 
{{WaterOverlay object nav}}

Revision as of 10:00, 4 April 2019

Pumps are constructions which can move water against its natural flow. Specifically, a pump with a positive pump speed will pump water from the entry point with the lowest initial water level to the entry point with the highest water level. If no water level is defined for an entry point, the surface height is taken.

Waterwizard icon pump q.png A pump is a line-based constructions. Template:Overlay attribute

Notes

  • A negative value for the PUMP_Q attribute is also allowed, in which case water can be pumped in the reverse direction.

See also