Oxidation formula (Subsidence Overlay)

From Tygron Support wiki
Revision as of 13:38, 9 February 2021 by Frank@tygron.nl (talk | contribs)
Jump to navigation Jump to search

The amount of subsidence due to oxidation is calculated by the following formula:

where

  • is the subsidence due to oxidation.
  • is the calculated ground water depth for year y.
  • is the calculated a parameter value for the current year .
  • is the clay thickness of the terrain, defined by CLAY_THICKNESS
  • is the b parameter value, defined by PARAMETER B
  • is the c parameter value, defined by PARAMETER C

This formula was provided by experts, who have derived this formula empirically.