UHI formula (Heat Overlay)

From Tygron Support wiki
Jump to navigation Jump to search

The Urban heat island effect is calculated using the following formula:
UHImax = ( 2 - Svf - Fveg ) * ( S * (Tmax-Tmin)3 / U )-4
where:

  • Svf is the calculated average sky view factor;
  • Fveg is the calculated average vegetation fraction;
  • S is the calculated daily average global radiation in K m/s
  • Tmax is the maximum temperature measured at a weather station between 8 AM and 7 AM the next day.
  • Tmin is the minimum temperature measured at a weather station between 8 AM and 7 AM the next day.


Formula Decomposition

The formula has two parts, the factor and the temperature effect:
UHImax = factor * temperature_effect

Factor

The factor is influenced by the sky view factor and the vegetation fraction, both ranging from 0 to 1. When both are low, i.e. barely any sky and no vegetation, the factor is near 2. When both are high, i.e. no surrounding buildings and a lot of vegetation, the factor is near 0.

Temperature effect

The Urban heat island temperature effect is calculated as:

Daily average global radiation

The S is calculated as followed:
ρair = p / Rspecific * (Tstation + 273.15)
S = Qql-avg / (Cair * ρair)
where,