Sewer overflows are points where water is moved from the sewer to the surface water system. A sewer overflow will allow water to flow through if the water in the sewer exceeds the SEWER_OVERFLOW_THRESHOLD, and the water in the connected sewer exceeds the height of the terrain at the location of the sewer overflow. It will then allow water to flow out of all sewers overflows part of that sewer area.

Waterwizard icon sewer overflow.png A sewer overflow is a point-based building. It must intersect with a sewer area but does not need to intersect with an actual sewered building.