Two temperature formulas are used in the calculation of the PET value and both are calculated per timeframe:

  • The atmospheric temperature Ta,t
  • The wet-bulb temperature[1] Tw,t

Atmospheric Temperature formula

Ta,t=Tstation,t+UHImax,t⋅fsun,t

where

Wet-bulb Temperature formula

Tw,t=Ta,t⋅arctan⁡(0.151977⋅ϕt+8.313659)+arctan⁡(Ta,t+ϕt)−arctan⁡(ϕt−1.676331)+(0.00391838⋅ϕt)32⋅arctan⁡(0.023101⋅ϕt)−4.686935

where: