Temperature formulas (Heat Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
Line 12: Line 12:


==Wet-bulb Temperature formula==
==Wet-bulb Temperature formula==
T<sub>w,t</sub> = T<sub>a,t</sub> · atan( 0.151977 · (ϕ + 8.313659)<sup>0.5</sup>) + atan (T<sub>a</sub> + ϕ) - atan(ϕ - 1.676331) + 0.00391838 · ϕ<sup>3/2</sup> atan(0.023101 · ϕ) - 4.686935<br>,
T<sub>w,t</sub> = T<sub>a,t</sub> · atan( 0.151977 · (ϕ + 8.313659)<sup>0.5</sup>) + atan (T<sub>a</sub> + ϕ) - atan(ϕ - 1.676331) + 0.00391838 · ϕ<sup>3/2</sup> atan(0.023101 · ϕ) - 4.686935<br>
where:
where:
* T<sub>w,t</sub> is the calculated wet-bulb temperature;
* T<sub>w,t</sub> is the calculated wet-bulb temperature;

Revision as of 09:34, 12 September 2019

Two temperature formulas are used in the calculation of the PET value:

  • The atmospheric temperature Ta
  • The wet-bulb temperatur Tw

Atmospheric Temperature formula

Ta,t = Tstation,t + UHImax,t · fsun,t
where,

Wet-bulb Temperature formula

Tw,t = Ta,t · atan( 0.151977 · (ϕ + 8.313659)0.5) + atan (Ta + ϕ) - atan(ϕ - 1.676331) + 0.00391838 · ϕ3/2 atan(0.023101 · ϕ) - 4.686935
where:

  • Tw,t is the calculated wet-bulb temperature;
  • Ta,t is the calculated atmospheric temperature;
  • ϕ is the sun altitude angle;

See also