==Wet-bulb Temperature formula== | ==Wet-bulb Temperature formula== | ||
<math>T_{w,t} = T_{a,t} \cdot \arctan( 0.151977 \cdot \sqrt{\ | <math>T_{w,t} = T_{a,t} \cdot \arctan( 0.151977 \cdot \sqrt{\phi_t + 8.313659})+ \arctan (T_{a} + \phi_t) - \arctan(\phi_t - 1.676331) + 0.00391838 \cdot \phi_t^{\frac{3}{2}} \arctan(0.023101 \cdot \phi_t) - 4.686935</math> | ||
where: | where: | ||
Revision as of 06:52, 13 October 2026
Two temperature formulas are used in the calculation of the PET value:
Atmospheric Temperature formula
where
- is the calculated atmospheric temperature at time t;
- is the temperature measured at a weather station at time t;
- is the calculated Urban Heat Island effect at time t;
- is the sun daily motion factor at time t;
Wet-bulb Temperature formula
where:
- is the calculated wet-bulb temperature;
- is the calculated atmospheric temperature;
- is the relative humidity
- Constant values are sourced from the DPRA Heat stress report;