Two temperature formulas are used in the calculation of the PET value:

  • The atmospheric temperature Ta
  • The wet-bulb temperatur Tw

Atmospheric Temperature formula

Ta,t=Tstation,t+UHImax,t⋅fsun,t

where

Wet-bulb Temperature formula

Tw,t=Ta,t⋅arctan⁡(0.151977⋅ϕ+8.313659)+arctan⁡(Ta+ϕ)−arctan⁡(ϕ−1.676331)+0.00391838⋅ϕ32arctan⁡(0.023101⋅ϕ)−4.686935

where:

  • Tw,t is the calculated wet-bulb temperature;
  • Ta,t is the calculated atmospheric temperature;
  • ϕ is the sun altitude angle;

See also