Revision as of 15:07, 11 September 2019
Two temperature formulas are used in the calculation of the PET value:
- The atmospheric temperature Ta
- The wet-bulb temperatur Tw
Atmospheric Temperature formula
Ta,t = Tstation,t + UHImax,t · fsun,t
where,
- Ta,t is the calculated atmospheric temperature at time t;
- Tstation,t is the temperature measured at a weather station at time t;
- UHImax,t is the calculated Urban Heat Island effect at time t;
- fsun,t is the sun daily motion factor at time t;
Wet-bulb Temperature formula
Tw = Ta · atan( 0.151977 · (ϕ + 8.313659)0.5) + atan (Ta + ϕ) - atan(ϕ - 1.676331) + 0.00391838 · ϕ3/2 atan(0.023101 · ϕ) - 4.686935