How to configure constant bottom boundary flow (Water Overlay): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
{{editor location|Overlay wizard|Water Overlay|Bottom boundary}}
{{editor location|Overlay wizard|Water Overlay|Bottom boundary}}


{{howto|title=configure constant seepage
{{howto|title=configure constant bottom boundary flow
| Open the [[Water Overlay Wizard]], and proceed to the ''bottom boundary'' step.
| Open the [[Water Overlay Wizard]], and proceed to the ''bottom boundary'' step.
| Opt to select Bottom Grid Overlays and define the seepage factor.
| Opt to select Bottom Grid Overlays
| Optionally define a [[Ground bottom pressure m (Water Overlay)|Global Pressure]].
| For the Head Pressure Grid, import your [[Bottom pressure prequel (Water Overlay)|GeoTIFF Overlay with head pressure values]].
| For the Head Pressure Grid, import your [[Bottom pressure prequel (Water Overlay)|GeoTIFF Overlay with head pressure values]].
| Ensure the uploaded [[GeoTIFF Overlay]] is selected in the dropdown.
| Ensure the uploaded [[GeoTIFF Overlay]] is selected in the dropdown.

Latest revision as of 11:42, 26 April 2024

When working with the full groundwater model of the Water Overlay, ground bottom flow from deeper ground layers through the bottom boundary may present a significant factor in the ground water balance. For these situations, various ground bottom flow parameters can be configured.

For ground bottom flow to be functional, the Bottom pressure prequel and Bottom resistance prequel are required and must be prepared beforehand.

Editor → Current Situation (Ribbon tab) → Overlays (Ribbon bar) → Water Overlay (Left panel) → Configuration Wizard (Right panel) → Bottom boundary
How to configure constant bottom boundary flow:
  1. Open the Water Overlay Wizard, and proceed to the bottom boundary step.
  2. Opt to select Bottom Grid Overlays
  3. Optionally define a Global Pressure.
  4. For the Head Pressure Grid, import your GeoTIFF Overlay with head pressure values.
  5. Ensure the uploaded GeoTIFF Overlay is selected in the dropdown.
  6. For the resistance Grid, import your GeoTIFF Overlay with resistance values.
  7. Ensure the uploaded GeoTIFF Overlay is selected in the dropdown.
  8. Close the configuration wizard, and recalculate the Overlay.